Aqua Lung Calypso Guía para resolver problemas

Busca en linea o descarga Guía para resolver problemas para Aletas De Buceo Aqua Lung Calypso. Aqua Lung Calypso Troubleshooting guide [de] [en] [fr] [ja] [zh] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Authorized Technician
TECHNICAL MAINTENANCE MANUAL
CALYPSO/TITAN/OCTOPUS
SECOND STAGE
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - SECOND STAGE

Authorized TechnicianTECHNICAL MAINTENANCE MANUALCALYPSO/TITAN/OCTOPUS SECOND STAGE

Pagina 2 - Contents

10 Lever Height Adjustment17. Pressurize the regulator18. Slide the notch of the ad-justing tool 125727 across the top of the box bottom (4) The

Pagina 3 - GENERAL GUIDELINES

Calypso/Titan Second Stage Service Manual 11 NOTE: If your facility is equipped with a test bench, perform the tests before installing the mouthpiec

Pagina 4 - DISASSEMBLY PROCEDURES

12 2. Observe any bubbles arising from the sub-merged regulator over a one minute period. The recommended time is necessary due to slower bubble f

Pagina 5

Calypso/Titan Second Stage Service Manual 13Table 1 - Troubleshooting GuideSYMPTOM POSSIBLE CAUSE TREATMENTLeak or freefl ow at 2nd Stage1. MP too h

Pagina 6

14 Table 2 - Recommended Tool ListPART NO. DESCRIPTION APPLICATION111610 I.P. test gauge Intermediate pressure testing944022 O-ring tools O-ring rem

Pagina 7 - REASSEMBLY PROCEDURES

Calypso/Titan Second Stage Service Manual 15Table 4 - Recommended Lubricants & CleanersLUBRICANT / CLEANER APPLICATION SOURCEChristo-Lube® MCG-1

Pagina 8

16 Procedure ACleaning & LubricationAqua Lung and Apeks Regulators and NitroxWhen it comes to issues of nitrox safety and compatibility, the con

Pagina 9

Calypso/Titan Second Stage Service Manual 17Table 6 - Test Bench Specifi cationsTEST CONDITION ACCEPTABLE RANGELeak Test Inlet 2,500-3,000 (±100) psi

Pagina 11 - FINAL TESTING PROCEDURES

Calypso/Titan Second Stage Service Manual 19Titan • Calypso • Octopus (2004 - present)Exploded Parts Diagram Key # Part # Description n/a ---

Pagina 12 - Subjective Breathing Test

2 ContentsCOPYRIGHT NOTICE...

Pagina 13

Authorized TechnicianTECHNICAL MAINTENANCE MANUALCALYPSO/TITAN/OCTOPUS SECOND STAGEAqua Lung America2340 Cousteau Court, Vista CA 92081Tel: 760-597-

Pagina 14

Calypso/Titan Second Stage Service Manual 3COPYRIGHT NOTICEThis manual is copyrighted, all rights reserved. It may not, in whole or in part, be copi

Pagina 15

4 GENERAL CONVENTIONSUnless otherwise instructed, the following terminology and tech-niques are assumed:1. When instructed to remove, unscrew, or l

Pagina 16 - Cleaning & Lubrication

Calypso/Titan Second Stage Service Manual 54. While holding the second stage secure, fi rmly grasp the collar of the front cover (1) which is seate

Pagina 17

6 NOTE: Because the crown is o-ring sealed, it will not freely exit the valve body after it has been disengaged. The following step must be perf

Pagina 18

Calypso/Titan Second Stage Service Manual 720. Place the handle of the extraction tool directly over the poppet bearing (20) in the top center of t

Pagina 19 - Exploded Parts Diagram

8 4. Using tool p/n 125727, engage the slotted head of the crown (14) and drive it in clockwise as far as the tool will allow. If the tool is not a

Pagina 20 - TECHNICAL MAINTENANCE MANUAL

Calypso/Titan Second Stage Service Manual 911. Place the washer (17) over the poppet shaft (22), followed by the locknut (16), with the fl at side f

Comentarios a estos manuales

Sin comentarios